Victron 24V 1600VA MultiPlus 24/1600/40-16 Inverter/Charger
Victron 24V 1600VA MultiPlus 24/1600/40-16 VE.Bus Inverter/Charger: A Comprehensive Power Solution for Marine, Vehicle, and Off-Grid Applications
Versatile Power Management for Diverse Environments
The Victron 24V Inverter/Charger extends beyond the capabilities of its predecessor to cater not only to commercial and industrial off-grid projects but also to the unique demands of marine environments, trucks, and buses. This advanced unit combines a true sine wave inverter, an adaptive technology battery charger, and a rapid AC transfer switch within a single compact unit. Its adaptability makes it an essential component for ensuring consistent, efficient energy supply across various applications.
Key Features and Benefits:
Enhanced Power Solutions for Multiple Domains
- Versatile Application: Ideal for marine vessels, commercial vehicles, and industrial off-grid systems, providing reliable power under varying conditions.
- Parallel and Three-Phase Operation: Similar to the 48V model, it supports up to six units in parallel for increased power output and three-phase configurations for balanced power distribution.
Tailored Power Management
- PowerControl for Limited Sources: Smartly manages generator or shore power to prevent overloads, adapting to your energy needs without compromise.
- PowerAssist for Added Power Boost: Seamlessly integrates battery power during peak demand periods, ensuring no interruption in power supply, then reverts to charging mode to optimize energy use.
Adaptive Charging for Maximum Efficiency
- Four-Stage Adaptive Charging: Automatically adjusts charging stages to suit battery conditions, prolonging battery life.
- Dual Bank Charging: Charges the main battery bank and a secondary battery, accommodating starter batteries for engines or generators.
Specialized Features for Enhanced Functionality
- High Start-Up Power: Capably starts high inrush loads, making it suitable for marine and vehicle applications where such loads are common.
- Efficient Operation with Search Mode: Reduces no-load power consumption significantly, ideal for conserving energy in vehicles and boats.
- Customizable Relay and Remote Options: Offers flexible configuration and remote monitoring capabilities, essential for managing systems remotely in vehicles and vessels.
Tailored for Marine, Vehicle, and Remote Industrial Use
- Power systems on boats and yachts, ensuring seamless operation away from shore.
- Energy management in commercial trucks and buses, supporting essential services and comfort systems.
- Remote industrial sites requiring dependable and efficient power distribution and management.
Simplified Configuration and Remote Monitoring
- Flexible Setting Adjustments: Utilize DIP switches, VE-Config, or the VE.Bus Smart dongle (not included) for easy on-site customization.
- Comprehensive Remote Management: With a Cerbo GX or similar device (not included), connect to the Victron VRM platform for detailed monitoring and control, a feature invaluable for fleet managers and marine operators.
Elevate Your Energy Solutions with Victron MultiPlus
The Victron 24V Inverter/Charger excels in providing robust, efficient, and versatile power solutions tailored to the needs of marine, vehicle, and off-grid applications. Its advanced features, combined with the ability to adapt to a variety of power demands, ensure optimal performance and reliability, making it the preferred choice for professionals seeking comprehensive power management capabilities.
Visit Victron Energy's Official MultiPlus Webpage for More Details
(PMP242160000)
Specifications
Model | MultiPlus 24/1600/40 |
PowerControl / PowerAssist | Yes |
Three Phase and parallel operation | Yes |
Transfer switch | 16 A |
Inverter | |
Input voltage range | 19 – 33 V |
Output | Output voltage: 230VAC ± 2% Frequency: 50Hz ± 0.1% (1) |
Cont. output power at 25°C^{(3)} Cont. output power at 25°C |
1600 VA 1300 W |
Cont. output power at 40°C | 1100 W |
Cont. output power at 65°C | 800 W |
Peak power | 2800 W |
Maximum efficiency | 94 % |
Zero-load power | 9 W |
Zero-load power in search mode | 3 W |
Charger | |
AC Input | Input voltage range: 187-265 VAC Input frequency: 45 – 65 Hz |
Charge voltage 'absorption' | 28.8 V |
Charge voltage 'float' | 27.6 V |
Storage mode | 26.4 V |
Charge current house battery^{(4)} | 40 A |
Charge current starter battery | 1A |
Battery temperature sensor | Yes |
General | |
Programmable relay | Yes |
Protection (2) | a – g |
VE.Bus communication port | For parallel and three phase operation, remote monitoring and system integration |
Remote on-off | On/off |
DIP switches | Yes^{(7)} |
Internal DC fuse | 125 A |
Common Characteristics | Operating temp. range: -40 to +65°C (fan assisted cooling) Humidity (non-condensing): max 95% |
Enclosure | |
Common Characteristics | Material & Colour: Steel/ABS (blue RAL 5012) Protection category: IP 21 Steel (RAL 5012), IP22 |
Battery-connection | 35 mm² |
230V AC-connection | G-ST18i connector |
Weight | 10.2 kg |
Dimensions (h x w x d) | 470 x 265 x 120 mm |
Standards | |
Safety | EN-IEC 60335-1, EN-IEC 60335-2-29, EN 62109-1 |
Emission Immunity | EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3, IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3 |
Automotive Directive | ECE R10-5 |
-
Adjustability
- Can be adjusted to 60Hz and to 240V.
-
Protection Features
- Output short circuit.
- Overload.
- Battery voltage too high.
- Battery voltage too low.
- Temperature too high.
- 230VAC on inverter output.
- Input voltage ripple too high.
-
Load Capacity
- Non-linear load, crest factor 3:1.
-
Operating Environment
- Up to 25°C ambient temperature.
-
Programmable Relay
- Can be set for general alarm, DC under voltage, or generator start/stop signal function.
- AC rating: 230V/4A.
- DC rating: 4A up to 35VDC, 1A up to 60VDC.
-
Control Options
- Remote control.
- Battery charge voltage adjustment.
- Inverter frequency adjustment.
- Search mode setting.
-
Battery and Inverter Settings
- Battery charge voltage adjustment.
- Search mode setting.
SKU | VIC-PMP242160000 |
Barcode # | 8719076044987 |
MPN # | PMP242160000 |
About Victron Energy Markets
Automotive
The automotive market comprises a broad range of applications requiring a reliable power supply. In vehicles such as fire engines, ambulances and police cars a human life may depend on an autonomous system. So it is vital that all systems function flawlessly. Victron Energy offers you such an answer. We are proud to offer you our modern translation for freedom and independence. Energy. Anytime. Anywhere.
Read Victron's Automotive Brochure
Off-Grid and Backup
The presence of a functional electricity grid is not always as obvious as it would seem to be. An insufficient infrastructure is often the cause for an unreliable grid. Things become even more difficult when there is no grid at all. And yet you are in need of a reliable electricity supply. A local and properly functioning system is the only answer at this point. Victron Energy offers you such an answer. We are proud to offer you our modern translation for freedom and independence. Energy, Anytime, Anywhere
Read Victron's Off-Grid and Backup Brochure
Marine
Whether you’re going on a short fishing trip or planning to sail across the ocean, you’ll need reliable power to enjoy your adventure to the fullest. But at Victron we believe reliability isn’t enough. We believe in Optimal Energy instead. In our view, a boat needs an intelligent power grid that adapts to any challenges you may encounter. With unparalleled reliability, without effort and at great value for money. That’s what we call Optimal Energy.
Read Victron's Marine Brochure
Energy Storage
As more solar and wind power comes on line, it becomes increasingly difficult and expensive, to ensure stability of the grid. Intermediate energy storage is therefore rapidly becoming an essential tool to keep power fluctuations on the grid within manageable limits. Moreover, as feed-in tariffs are decreasing, the business case for a home energy storage system that increases self-consumption becomes more solid every day. Intermediate energy storage increases self-consumption of harvested solar and/or wind power. The natural next step is 100% self-consumption and independence from the grid.
Read Victron's Off-Grid and Backup Brochure
Read the Victron Wiring Guide - Wiring Unlimited
Download the VictronConnect App Here
Helpful Victron Videos
Did You Know - Choosing the right MPPT for your solar by using our calculator
How to not blow up your Alternator when charging a Lithium Battery with a DC-DC Charger
Victron Energy Limited Warranty Policy
Victron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years from the date of purchase by the end user, with a maximum of 66 months from the Victron Energy invoice date. Exceptions on this are: lead acid batteries; 2 years from date of purchase by the end user, with a maximum of 30 months from the Victron Energy invoice date, Lithium-ion batteries; 3 years from date of purchase by the end user. In addition to this proof of correct battery usage is required when making a battery warranty claim.
During this period, Victron Energy will, at its option, repair or replace the defective product free of charge. The warranty does not include performing or reimbursing de‐installation, transportation and re‐installation. This warranty will be considered void if the unit has suffered any physical damage or alteration, either internally or externally, and does not cover damages arising from improper use like:
• Reverse of battery polarity.
• Inadequate connection.
• Mechanical shock or deformation.
• Contact with liquid or oxidation by condensation.
• Use in inappropriate environment (dust, corrosive vapor, humidity, high temperature, biological infestation...).
• Breakage or damage due to lightning.
• Connection terminals and screws destroyed or other damages, like overheat, due to insufficient tightening.
• For any electronical breakage except due to lightning (reverse polarity, over‐voltage due to external cause), the state ofthe internal control diode and of the inputs/output X and Y capacitors determine the warranty.
This warranty will not apply where the product has been misused, neglected, improperly installed, or repaired by anyone else than Victron Energy or one of its authorized Qualified Service Partners. In order to qualify for the warranty, the product must not be disassembled or modified.
Repair or replacement are our sole remedies and Victron Energy shall not be liable for damages, whether direct, incidental,special, or consequential, even caused by negligence or fault.
Victron Energy owns all parts removed from repaired products. Victron Energy uses new or reconditioned parts made by various manufacturers in performing warranty repairs and building replacement products. If Victron Energy repairs or replaces a part of a product, its warranty term is not extended. In case of replacement the new component has a warranty of 6 months, without effect on the initial warranty period. All remedies and the measure for damages are limited to the above. Victron Energy shall in no event be liable for consequential, incidental, contingent orspecial damages, even if having been advised of the probability of such damages. Any and all other warranties expressed or implied arising by law, course of dealing, course of performance, usage of trade or otherwise, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited in duration to a period of two (2) years from the date of purchase.
Life Support Policy
As a general policy, Victron Energy, does not recommend the use of any of its products in life support applications where failure or malfunction of the Victron Energy's product can be reasonably expected to cause failure of the life support device or to significantly affect its safety or effectiveness. Victron Energy does not recommend the use of any of its products in direct patient care. Victron Energy will not knowingly sell its products for use in such applications unless it receives in writing assurances satisfactory to Victron Energy that the risks of injury or damage have been minimized, the customer assumes all such risks, and the Liability of Victron Energy is adequately protected under the circumstances.
As a product requires service, it must be brought back to the place of purchase. In case no contact can be taken with the merchant, or if he is either unable or not allowed to provide service, direct contact should be taken with Victron Energy.
Warranty on Repairs
The warranty period on products or on printed circuits boards repaired by Victron Energy as well as on printed circuit boards for replacement is 6 months from delivery by Victron Energy.
Transport
It is the responsibility of the sender to sufficiently package these products. The transport must be organized in a way to avoid any damage, especially when a single unit or heavy unit is sent.
Severability
If a part of the terms and conditions set out above is held invalid, void or unenforceable due to any particular national or international legislation, it shall not affect other parts of the terms and conditions remaining.
For Australia only
Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.