Victron Lynx Smart BMS 500 M8
Please allow 2 business days before dispatch
Optimize Your Energy Storage with Lynx Smart 500A BMS M8 for Victron Lithium Batteries
Discover the pinnacle of battery management with the Lynx Smart BMS, designed exclusively for Victron Lithium Battery Smart series. These high-efficiency Lithium Iron Phosphate (LiFePO4) batteries come in 12.8V and 25.6V across various capacities, perfect for diverse energy needs.
Versatile Configuration for Maximum Power: Configure these batteries in series, parallel, or series/parallel combinations to build a robust battery bank for 12V, 24V, or 48V systems. With a capacity to integrate up to 20 batteries, achieve impressive energy storage of up to 84 kWh in a 12V system and up to 102 kWh in 24V and 48V systems.
Feature-Rich BMS Solution: The Lynx Smart BMS stands out as the most comprehensive and advanced BMS available, seamlessly integrating into the Lynx Distributor system.
Advanced Safety and Control Mechanisms:
- Built-in Contactor: Acts as a secondary safety system, doubling as a remote-controllable main system switch.
- Pre-Charge Circuit: Prevents high inrush currents, simplifying your setup by eliminating the need for external pre-charging.
Monitoring and control
Monitor and control the BMS via Bluetooth using the VictronConnect App or a GX device such as a Cerbo GX and the VRM Portal. A built-in battery monitor that operates in a similar fashion as the other Victron Energy battery monitors, provides data such as state of charge, voltage, current, historical data, status info and more in real time, and with Instant Readout even without the need to connect to the BMS, allowing diagnostic at a glance.
Intelligent System Integration:
Compatible Victron inverter/chargers and solar chargers are automatically controlled via a connected GX device and DVCC. The ATC/ATD contacts can be used to control other chargers and loads that have a remote on/off port.
Programmable relay
The relay can be used either as an alarm relay (combined with the pre-alarm) or to control an alternator via its external regulator (ignition cable). In Alternator ATC mode, the relay will only activate when the contactor is closed. Alternator ATC contact of the alternator opens first and then with a delay of 2 seconds the contactor. These 2 seconds ensure that the alternator is switched off before the battery is disconnected from the system.
AUX Terminal
The advantage of the onboard auxiliary power supply (1.1 A @ system voltage) is to provide power to specific loads (i.e. a GX device) after the BMS has shut down the loads in the event of a low cell voltage event. If no charge voltage is detected within 5 minutes, the BMS including the AUX connection switches off.
VE.Can and NMEA 2000 data communication
VE.Can allows for easy connection (standard RJ45 network cable) and communication with a GX device. Since the CANbus protocol is based on NMEA 2000 (and J1939), it is easy to integrate into a marine network and feed your marine MFD with data (requires a VE.Can to NMEA 2000 micro-C male cable).
Lynx Distributor fuse monitoring
Read out fuse status and receive an alarm in case a fuse is blown. The Lynx Smart BMS monitors up to 4 connected Lynx Distributors and their fuses via VictronConnect or a GX device
1) To reduce required balancing time, we recommend to use a little different batteries in series as possible for the application. 24 V systems are best built using 24 V batteries. And 48 V systems are best built using two 24 V batteries in series. While the alternative, four 12 V batteries in series, will work, it will require more periodic balancing time.
Visit Victron's Official Lynx Smart BMS Webpage for More Details
(LYN034160200)
Specifications
Lynx Smart BMS | 500 A |
Power | |
Battery voltage range | 9 – 60 VDC |
Maximum input voltage | 75 VDC |
Supported system voltages | 12, 24 or 48 V |
Reverse polarity protection | No |
Main safety contactor continuous current rating | 500 A continuous |
Main safety contactor peak current rating | 600 A for 5 minutes |
Power consumption OFF mode | 0.3 mA for all system voltages |
Power consumption in Standby mode | Approximately 0.6 W (50 mA at 12 V) |
Power consumption in ON mode | Approx. 2.6 W (217 mA at 12 V) depending on the state of the relays |
Minimum load resistance for pre-charging | 10 Ω and above for 12 V systems 20 Ω and above for 24 V and 48 V systems |
AUX output maximum current rating | 1.1 A continuous, protected by resettable fuse |
Allow-to-charge port Maximum current rating |
0.5 A at 60 VDC, protected by resettable fuse |
Allow-to-discharge port Maximum current rating |
0.5 A at 60VDC, protected by resettable fuse |
Alarm relay (SPDT) Maximum current rating |
2 A at 60 VDC |
Connections | |
Busbar | M8 (Torque: 14 Nm) |
VE.Can | RJ45 |
I/O | Removable multi-connector with screw terminals |
Battery BTV cables | Male and female circular 3-pole connector with M8 screw ring Up to 20 batteries can be connected in one system |
Lynx Distributor fuse monitoring (up to 4 modules) | RJ10 (cable ships with each Lynx Distributor) |
Physical | |
Enclosure material | ABS |
Enclosure dimensions (h x w x d) | 190 x 180 x 80 mm |
Unit weight | 1.9 kg |
Busbar material | Tinned copper |
Busbar dimensions (h x w) | 8 x 30 mm |
Environmental | |
Operating temperature range | -40 °C to +60 °C |
Storage temperature range | -40 °C to +60 °C |
Humidity | Max. 95 % (non-condensing) |
Protection class | IP22 |
Standards | |
Safety | EN-IEC 63000:2018 |
EMC | EN-IEC 61000-6-3:2007/A1:2011/AC:2012 |
QMS | NEN-EN-ISO 9001:2015 |
SKU | VIC-LYN034160200 |
Barcode # | 8719076047476 |
MPN # | LYN034160200 |
About Victron Energy Markets
Automotive
The automotive market comprises a broad range of applications requiring a reliable power supply. In vehicles such as fire engines, ambulances and police cars a human life may depend on an autonomous system. So it is vital that all systems function flawlessly. Victron Energy offers you such an answer. We are proud to offer you our modern translation for freedom and independence. Energy. Anytime. Anywhere.
Read Victron's Automotive Brochure
Off-Grid and Backup
The presence of a functional electricity grid is not always as obvious as it would seem to be. An insufficient infrastructure is often the cause for an unreliable grid. Things become even more difficult when there is no grid at all. And yet you are in need of a reliable electricity supply. A local and properly functioning system is the only answer at this point. Victron Energy offers you such an answer. We are proud to offer you our modern translation for freedom and independence. Energy, Anytime, Anywhere
Read Victron's Off-Grid and Backup Brochure
Marine
Whether you’re going on a short fishing trip or planning to sail across the ocean, you’ll need reliable power to enjoy your adventure to the fullest. But at Victron we believe reliability isn’t enough. We believe in Optimal Energy instead. In our view, a boat needs an intelligent power grid that adapts to any challenges you may encounter. With unparalleled reliability, without effort and at great value for money. That’s what we call Optimal Energy.
Read Victron's Marine Brochure
Energy Storage
As more solar and wind power comes on line, it becomes increasingly difficult and expensive, to ensure stability of the grid. Intermediate energy storage is therefore rapidly becoming an essential tool to keep power fluctuations on the grid within manageable limits. Moreover, as feed-in tariffs are decreasing, the business case for a home energy storage system that increases self-consumption becomes more solid every day. Intermediate energy storage increases self-consumption of harvested solar and/or wind power. The natural next step is 100% self-consumption and independence from the grid.
Read Victron's Off-Grid and Backup Brochure
Read the Victron Wiring Guide - Wiring Unlimited
Download the VictronConnect App Here
Helpful Victron Videos
Did You Know - Choosing the right MPPT for your solar by using our calculator
How to not blow up your Alternator when charging a Lithium Battery with a DC-DC Charger
Victron Energy Limited Warranty Policy
Victron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years from the date of purchase by the end user, with a maximum of 66 months from the Victron Energy invoice date. Exceptions on this are: lead acid batteries; 2 years from date of purchase by the end user, with a maximum of 30 months from the Victron Energy invoice date, Lithium-ion batteries; 3 years from date of purchase by the end user. In addition to this proof of correct battery usage is required when making a battery warranty claim.
During this period, Victron Energy will, at its option, repair or replace the defective product free of charge. The warranty does not include performing or reimbursing de‐installation, transportation and re‐installation. This warranty will be considered void if the unit has suffered any physical damage or alteration, either internally or externally, and does not cover damages arising from improper use like:
• Reverse of battery polarity.
• Inadequate connection.
• Mechanical shock or deformation.
• Contact with liquid or oxidation by condensation.
• Use in inappropriate environment (dust, corrosive vapor, humidity, high temperature, biological infestation...).
• Breakage or damage due to lightning.
• Connection terminals and screws destroyed or other damages, like overheat, due to insufficient tightening.
• For any electronical breakage except due to lightning (reverse polarity, over‐voltage due to external cause), the state ofthe internal control diode and of the inputs/output X and Y capacitors determine the warranty.
This warranty will not apply where the product has been misused, neglected, improperly installed, or repaired by anyone else than Victron Energy or one of its authorized Qualified Service Partners. In order to qualify for the warranty, the product must not be disassembled or modified.
Repair or replacement are our sole remedies and Victron Energy shall not be liable for damages, whether direct, incidental,special, or consequential, even caused by negligence or fault.
Victron Energy owns all parts removed from repaired products. Victron Energy uses new or reconditioned parts made by various manufacturers in performing warranty repairs and building replacement products. If Victron Energy repairs or replaces a part of a product, its warranty term is not extended. In case of replacement the new component has a warranty of 6 months, without effect on the initial warranty period. All remedies and the measure for damages are limited to the above. Victron Energy shall in no event be liable for consequential, incidental, contingent orspecial damages, even if having been advised of the probability of such damages. Any and all other warranties expressed or implied arising by law, course of dealing, course of performance, usage of trade or otherwise, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited in duration to a period of two (2) years from the date of purchase.
Life Support Policy
As a general policy, Victron Energy, does not recommend the use of any of its products in life support applications where failure or malfunction of the Victron Energy's product can be reasonably expected to cause failure of the life support device or to significantly affect its safety or effectiveness. Victron Energy does not recommend the use of any of its products in direct patient care. Victron Energy will not knowingly sell its products for use in such applications unless it receives in writing assurances satisfactory to Victron Energy that the risks of injury or damage have been minimized, the customer assumes all such risks, and the Liability of Victron Energy is adequately protected under the circumstances.
As a product requires service, it must be brought back to the place of purchase. In case no contact can be taken with the merchant, or if he is either unable or not allowed to provide service, direct contact should be taken with Victron Energy.
Warranty on Repairs
The warranty period on products or on printed circuits boards repaired by Victron Energy as well as on printed circuit boards for replacement is 6 months from delivery by Victron Energy.
Transport
It is the responsibility of the sender to sufficiently package these products. The transport must be organized in a way to avoid any damage, especially when a single unit or heavy unit is sent.
Severability
If a part of the terms and conditions set out above is held invalid, void or unenforceable due to any particular national or international legislation, it shall not affect other parts of the terms and conditions remaining.
For Australia only
Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.